<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-25 11-59-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 57 kHz 16905 6,5779
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,5 dBr 2,48 dBr 3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 57 kHz MIN: 13 kHz % above 76 kHz: 6,5779 Acquired: 2024/08/25 11.58.06 Total samples: 16905 Equivalent time: 0:14:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,8 dBr MIN: 1,5 dBr AVE: 2,48 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2024/08/25 11.58.05) 11.44 11.46 11.48 11.50 11.52 11.54 11.56 11.58 -1 0 1 2 3 4 Pm [dBr]